Updated meter mode comes with case and calibration kit >SEE >> HERE
This combined pH & EC Meter gives accurate readings of nutrient solution and is very helpful in mixing right nutrient concentrate for plants with hydroponics and with soil growing.
With this meter you can measure:
Features of the combined Ec and ph meter:
-
Take the water temperature into account when calculating the measurement result
-
Temporarily waterproof, but only immerse the measuring head in the water tank
-
The meter is calibrated before sending to the customer
-
The pH and EC value of the meter can be adjusted and it is advisable to calibrate the meter every few months using the appropriate calibration agents.
-
Includes batteries and adjustment tool for calibration
-
One year warranty
How to use EC and pH meter
All meter readings are automatically temperature compensated. It is easy-to-use as you can just dip the sensor into the test solution - stir and wait. This unit will deliver a stable reading in about 10 - 20 seconds.
The EC value of plant nutrient water for e.g. herbs should be 1.2, which in the meter is 120 (= EC 1.2), but the nutrient value can vary between 080-250 for different plants. To adjust the EC value in water; add clean water to lower EC value or to increase EC value add nutrient solution to the water tank. To lower the too high EC value of full water tank, the water must be replaced at least partly with new neutral water.
The pH of plant nutrient water should be about 5.8 (between 5.4 and 6.2). To correct the water pH value add some pH + or - adjusters that can be found from the store.
CALIBRATION OF THE pH & EC METER
EC and pH measurements should be calibrated every few months. There is included screw driver for this with the meter.
Calibrate the meter using pH buffer agents and EC calibrators found in the store.
Calibration of the meter to pH 7
-
Open the screw cap on the meter, which shows the batteries
-
Use the EC / pH button to select the pH to be measured, the display will show a low PH
-
Remove the probe cap, immerse the probe in the pH 7 solution
-
Wait for the meter to stabilize, then adjust the meter to 7.00 by turning the small PH screw next to the batteries.
-
Rinse the meter head with water and replace the protective cap
Calibration of the meter to pH 4
-
By also calibrating the meter to pH 4, you ensure that the meter is calibrated over the entire measuring range
-
Remove the probe cap, immerse the probe in the pH 4 solution
-
Wait for the meter to stabilize, then adjust the meter to 4.00 by turning the small PH screw next to the batteries.
-
Rinse the meter head with water and replace the protective cap
EC calibration of the meter
-
Open the screw cap on the meter, which shows the batteries
-
Select EC to measure with the EC / pH button, the display will read X10 US with a small
-
Remove the probe cap, immerse the probe in the EC / CF calibration solution
-
Wait for the meter reading to stabilize, then adjust the meter to 280 by turning the small TDC / EC screw next to the batteries.
-
Rinse the meter head with water and replace the protective cap
Pen type Waterproof PH/EC & TEMP Meter
|
Measuring range
|
pH: 0.00~14.00
EC: 0~19990us/cm
Temp: -50℃~70℃(-58℉-158℉)
|
Resolution
|
Ph :0.01
EC:10us/cm
Temp: 0.1℃(0.2℉)
|
Accuracy
|
PH: ±0.1
EC:±2%F.S
TEMP: ±1℃(±2℉)
|
Power Supply
|
DC6V
|
Temperature Compensation
|
0 to 50℃
|
Working temperature
|
0-50℃
|